A9 - A300 | LIGHTING CONTACTORS | ELECTRICALLY & MECHANICALLY HELD | AC OPERATED
APPLICATION
ABB Lighting Contactors can be used to control a variety of lighting loads including parking lots, industrial plants, office buildings, stadiums, shopping centers, airports, hospitals, institutions, theaters, & more.COIL SELECTION
All catalog numbers include a 120VAC coil. To select other coil voltages, substitute the code from the Coil Voltage Selection Chart for the two digits after the last dash in the catalog number.COIL VOLTAGE SELECTION CHART
Hz | Cntr Type | Volts | |||||||||||||||
12 | 24 | 48 | 110 | 120 | 125 | 208 | 220 | 240 | 277 | 380 | 415 | 440 | 480 | 500 | 600 | ||
60 | A | 81 | 83 | 84 | 84 | 34 | 36 | 80 | 42 | 86 | 86 | 51 | 53 | 55 | |||
50 | A | 81 | 83 | 84 | 80 | 85 | 86 | 55 |
STANDARD PART NUMBERS | (2 & 3 Pole - 600 Volt N.O. ratings / 300 volt N.C. dynamic braking)
Normally Closed Power Poles | Electrically Held | Mechanically Held | ||||||
Open Type | UL Type 1 Enclosed | Open Type | UL Type 1 Enclosed | |||||
Ballast Amp Rating | Incandescent (Tungsten) Amp Rating | # of Power Poles | Catalog Number | Encl Size | Catalog Number | Catalog Number | Encl Size | Catalog Number |
30 | 20 | 4 | A16-04-00-84 | A | A16C4NCP1-84 | A16L-04-00-84 | A | A16LC4NCP1-84 |
30 | 20 | 8 | A16-08-00-84 | A | A16C8NCP1-84 | A16L-08-00-84 | A | A16LC8NCP1-84 |
30 | 20 | 12 | A16-012-00-84 | A | A16C12NCP1-84 | A16L-012-00-84 | A | A16LC12NCP1-84 |
2 NO & 2 NC Power Poles | Electrically Held | Mechanically Held | ||||||
Open Type | UL Type 1 Enclosed | Open Type | UL Type 1 Enclosed | |||||
Ballast Amp Rating | Incandescent (Tungsten) Amp Rating | # of Power Poles | Catalog Number | Encl Size | Catalog Number | Catalog Number | Encl Size | Catalog Number |
15 | 15 | 2NO/2NC | A9-22-00-84 | A | A9C22P1-84 | A9L-22-00-84 | A | A9LC22P1-84 |
30 | 20 | 2NO/2NC | A16-22-00-84 | A | A16C22P1-84 | A16L-22-00-84 | A | A16LC22P1-84 |
35 | 35 | 2NO/2NC | A26-22-00-84 | A | A26C22P1-84 | A26L-22-00-84 | B | A26LC22P1-84 |
60 | 60 | 2NO/2NC | A45-22-00-84 | B | A45C22CP1-84 | A45L-22-00-84 | C | A45LC22CP1-84 |
105 | 105 | 2NO/2NC | A75-22-00-84 | B | A75C22CP1-84 | A75L-22-00-84 | C | A75LC22CP1-84 |
NEMA Rated - NO Power Poles 600 VAC Max. |
Electrically Held Open Type |
||
Ballast Amp Rating | Incandescent (Tungsten) Amp Rating | # of Power Poles | Catalog Number |
30 | 30 | 3 | L30A3010∆ |
60 | 60 | 3 | L60A3010∆ |
100 | 100 | 3 | L100A3000∆ |
200 | 200 | 3 | L200A3000∆ |
∆ To select a coil voltage, substitute the code from the Coil Voltage Selection Chart for the ∆.