All AC operated catalog numbers include a 120VAC coil. To select other coil voltages, substitute the code from the Coil Voltage Selection Chart for the two digits after the last dash in the catalog number.STANDARD PART NUMBERS | OPEN & ENCLOSED
UL Motor Switching Current |
Maximum Ratings - UL Listed | Open Type | UL Type 1 (Indoor Metal) |
UL Type 3R (Outdoor Metal) |
|||
Maximum Motor Horsepower Ratings | |||||||
200/208V | 230/240V | 460/480V | 575/600V | Catalog Number | Catalog Number | Catalog Number | |
UL RATED | |||||||
9 | 2 | 2 | 5 | 7.5 | 12-2∆ | 121-2∆ | 123-2∆ |
11 | 3 | 3 | 7.5 | 10 | 22-2∆ | 221-2∆ | 223-2∆ |
17 | 5 | 5 | 10 | 15 | 32-2∆ | 321-2∆ | 323-2∆ |
28 | 7.5 | 10 | 20 | 25 | 42-2∆ | 421-2∆ | 423-2∆ |
34 | 10 | 10 | 25 | 30 | 52-2∆ | 521-2∆ | 523-2∆ |
42 | 10 | 15 | 30 | 40 | 62-2∆ | 621-2∆ | 623-2∆ |
54 | 15 | 20 | 40 | 50 | 72-2∆ | 721-2∆ | 723-2∆ |
65 | 20 | 25 | 50 | 50 | 82-2∆ | 821-2∆ | 823-2∆ |
80 | 25 | 30 | 60 | 75 | 92-2∆ | 921-2∆ | 923-2∆ |
110 | 30 | 40 | 75 | 100 | A2-2∆ | A21-2∆ | A23-2∆ |
130 | 40 | 50 | 100 | 125 | B2-2∆ | B21-2∆ | B23-2∆ |
156 | 50 | 60 | 125 | 150 | C2-2∆ | C21-2∆ | C23-2∆ |
192 | 60 | 75 | 150 | 200 | D2-2∆ | D21-2∆ | D23-2∆ |
248 | 75 | 100 | 200 | 250 | E2-2∆ | E21-2∆ | E23-2∆ |
302 | 100 | 100 | 250 | 300 | F2-2∆ | F21-2∆ | F23-2∆ |
414 | 125 | 150 | 350 | 400 | G2-70∆ | G21-70∆ | G23-70∆ |
480 | 150 | 200 | 400 | 500 | H2-70∆ | H21-70∆ | H23-70∆ |
590 | 200 | 250 | 500 | 600 | T2-70∆ | T21-70∆ | T23-70∆ |
810 | 250 | 300 | 600 | 700 | U2-70∆ | U21-70∆ | U23-70∆ |
NEMA Rated | |||||||||
Open Type | UL Type 1 (Indoor Metal) |
UL Type 3R (Outdoor Metal) |
|||||||
NEMA Size | Continuous Current |
200V | 230V | 460/575V | Catalog Number | Catalog Number | Catalog Number | ||
00 | 9 | 1.5 | 1.5 | 2 | J2-2∆ | J21-2∆ | J23-2∆ | ||
0 | 18 | 3 | 3 | 5 | K2-2∆ | K21-2∆ | K23-2∆ | ||
1 | 27 | 7.5 | 7.5 | 10 | L2-2∆ | L21-2∆ | L23-2∆ | ||
2 | 45 | 10 | 15 | 25 | M2-2∆ | M21-2∆ | M23-2∆ | ||
3 | 90 | 25 | 30 | 50 | N2-2∆ | N21-2∆ | N23-2∆ | ||
4 | 135 | 40 | 50 | 100 | P2-2∆ | P21-2∆ | P23-2∆ | ||
5 | 270 | 75 | 100 | 200 | Q2-2∆ | Q21-2∆ | Q23-2∆ | ||
6 | 540 | 150 | 200 | 400 | R2-70∆ | R21-70∆ | R23-70∆ | ||
7 | 810 | - | 300 | 600 | S2-70∆ | S21-70∆ | S23-70∆ |
UL Motor Switching Current |
Maximum Ratings - UL Listed | UL Type 12 (Metal Dustight) |
UL Type 4 (Watertight) |
|||
Maximum Motor Horsepower Ratings | ||||||
200/208V | 230/240V | 460/480V | 575/600V | Catalog Number | Catalog Number | |
UL RATED | ||||||
9 | 2 | 2 | 5 | 7.5 | 122-2∆ | 124-2∆ |
11 | 3 | 3 | 7.5 | 10 | 222-2∆ | 224-2∆ |
17 | 5 | 5 | 10 | 15 | 322-2∆ | 324-2∆ |
28 | 7.5 | 10 | 20 | 25 | 422-2∆ | 424-2∆ |
34 | 10 | 10 | 25 | 30 | 522-2∆ | 524-2∆ |
42 | 10 | 15 | 30 | 40 | 622-2∆ | 624-2∆ |
54 | 15 | 20 | 40 | 50 | 722-2∆ | 724-2∆ |
65 | 20 | 25 | 50 | 50 | 822-2∆ | 824-2∆ |
80 | 25 | 30 | 60 | 75 | 922-2∆ | 924-2∆ |
110 | 30 | 40 | 75 | 100 | A22-2∆ | A24-2∆ |
130 | 40 | 50 | 100 | 125 | B22-2∆ | B24-2∆ |
156 | 50 | 60 | 125 | 150 | C22-2∆ | C24-2∆ |
192 | 60 | 75 | 150 | 200 | D22-2∆ | D24-2∆ |
248 | 75 | 100 | 200 | 250 | E22-2∆ | E24-2∆ |
302 | 100 | 100 | 250 | 300 | F22-2∆ | F24-2∆ |
414 | 125 | 150 | 350 | 400 | G22-70∆ | G24-70∆ |
480 | 150 | 200 | 400 | 500 | H22-70∆ | H24-70∆ |
590 | 200 | 250 | 500 | 600 | T22-70∆ | T24-70∆ |
810 | 250 | 300 | 600 | 700 | U22-70∆ | U24-70∆ |
NEMA Rated | ||||||||
UL Type 12 (Metal Dustight) |
UL Type 4 (Watertight) |
|||||||
NEMA Size | Continuous Current |
200V | 230V | 460/575V | Catalog Number | Catalog Number | ||
00 | 9 | 1.5 | 1.5 | 2 | J22-2∆ | J24-2∆ | ||
0 | 18 | 3 | 3 | 5 | K22-2∆ | K24-2∆ | ||
1 | 27 | 7.5 | 7.5 | 10 | L22-2∆ | L24-2∆ | ||
2 | 45 | 10 | 15 | 25 | M22-2∆ | M24-2∆ | ||
3 | 90 | 25 | 30 | 50 | N22-2∆ | N24-2∆ | ||
4 | 135 | 40 | 50 | 100 | P22-2∆ | P24-2∆ | ||
5 | 270 | 75 | 100 | 200 | Q22-2∆ | Q24-2∆ | ||
6 | 540 | 150 | 200 | 400 | R22-70∆ | R24-70∆ | ||
7 | 810 | - | 300 | 600 | S22-70∆ | S24-70∆ |
UL Motor Switching Current |
Maximum Ratings - UL Listed | UL Type 4X (Stainless Steel) |
UL Type 1, 3R, 4, 4Z & 12 (Plastic) |
|||
Maximum Motor Horsepower Ratings | ||||||
200/208V | 230/240V | 460/480V | 575/600V | Catalog Number | Catalog Number | |
UL RATED | ||||||
9 | 2 | 2 | 5 | 7.5 | 12X-2∆ | 12P-2∆ |
11 | 3 | 3 | 7.5 | 10 | 22X-2∆ | 22P-2∆ |
17 | 5 | 5 | 10 | 15 | 32X-2∆ | 32P-2∆ |
28 | 7.5 | 10 | 20 | 25 | 42X-2∆ | 42P-2∆ |
34 | 10 | 10 | 25 | 30 | 52X-2∆ | 52P-2∆ |
42 | 10 | 15 | 30 | 40 | 62X-2∆ | 62P-2∆ |
54 | 15 | 20 | 40 | 50 | 72X-2∆ | 72P-2∆ |
65 | 20 | 25 | 50 | 50 | 82X-2∆ | 82P-2∆ |
80 | 25 | 30 | 60 | 75 | 92X-2∆ | 92P-2∆ |
110 | 30 | 40 | 75 | 100 | A2X-2∆ | A2P-2∆ |
130 | 40 | 50 | 100 | 125 | B2X-2∆ | B2P-2∆ |
156 | 50 | 60 | 125 | 150 | C2X-2∆ | C2P-2∆ |
192 | 60 | 75 | 150 | 200 | D2X-2∆ | D2P-2∆ |
248 | 75 | 100 | 200 | 250 | E2X-2∆ | E2P-2∆ |
302 | 100 | 100 | 250 | 300 | F2X-2∆ | F2P-2∆ |
414 | 125 | 150 | 350 | 400 | G2X-70∆ | - |
480 | 150 | 200 | 400 | 500 | H2X-70∆ | - |
590 | 200 | 250 | 500 | 600 | T2X-70∆ | - |
810 | 250 | 300 | 600 | 700 | U2X-70∆ | - |
NEMA Rated | ||||||||
UL Type 4X (Stainless Steel) |
UL Type 1, 3R, 4, 4Z & 12 (Plastic) |
|||||||
NEMA Size | Continuous Current |
200V | 230V | 460/575V | Catalog Number | Catalog Number | ||
00 | 9 | 1.5 | 1.5 | 2 | J2X-2∆ | J2P-2∆ | ||
0 | 18 | 3 | 3 | 5 | K2X-2∆ | K2P-2∆ | ||
1 | 27 | 7.5 | 7.5 | 10 | L2X-2∆ | L2P-2∆ | ||
2 | 45 | 10 | 15 | 25 | M2X-2∆ | M2P-2∆ | ||
3 | 90 | 25 | 30 | 50 | N2X-2∆ | N2P-2∆ | ||
4 | 135 | 40 | 50 | 100 | P2X-2∆ | P2P-2∆ | ||
5 | 270 | 75 | 100 | 200 | Q2X-2∆ | Q2P-2∆ | ||
6 | 540 | 150 | 200 | 400 | R2X-70∆ | - | ||
7 | 810 | - | 300 | 600 | S2X-70∆ | - |
∆ Overload relay suffix code. Select from Overload Relay Selection Chart.
COIL VOLTAGE SELECTION CHART (A9-A300)
Hz | Cntr Type | Volts | |||||||||
24 | 110 | 120 | 208 | 220 | 240 | 440 | 480 | 500 | 600 | ||
60 | A | 1 | 2 | 3 | 4 | 5 | 6 | 7 | |||
50 | A | 1 | 2 | 4 | 7 |
COIL VOLTAGE SELECTION CHART (AF400-A750)1
Hz | Type | 100 - 250 | 250 - 500 |
50/60 | AF | 70 | 71 |
CONTROL TRANSFORMER VOLTAGE SELECTION CHART
Volts | |||||
Hz | Type | 200 - 208/120 | 240/120 | 460 - 480/120 | 575 - 600/120 |
50/60 | A/AF | A | B | C | D |
200 - 208/24 | 240/24 | 460 - 480/24 | 575 - 600/24 | ||
E | F | G | H |
CONTROL TRANSFORMER OPTION
Contactor Size | VA Rating |
A9 - A40 | 50 |
A50 - A75 | 75 |
A95 - A110 | 100 |
A145 - A185 | 150 |
A210 - A300 | 250 |
A400 - A460 | 150 |
A580 - A750 | 250 |
1 No primary fusing provided.