Call Us Toll-Free: (877) 268-3700 | sales@grossautomation.com
B6 & B7 | MINIATURE CONTACTORS | MECHANICALLY INTERLOCKED | 3 PHASE
APPLICATION
- Low power consumption coils
- Self-lifting cable clamps
- Panel or DIN rail mounting
- Snap-on accessories
- UL Listed, file # E39231
- Applications include use in machines, electrical appliances, building automation systems, heating systems, overhead door applications, etc.
MECHANICALLY INTERLOCKED WITH SCREW CONNECTIONS
General Purpose AC1 |
Maximum Motor FLA AC3 |
3 Phase Motor Horsepower | Single Phase | Number of Power Poles |
Auxiliary Contacts |
Catalog Number | ||||
208V | 230V | 460V | 600V | 120V | 230V | |||||
AC OPERATED | ||||||||||
12 | 6.8 | 1 | 2 | 3 | 1 | 1/2 | 1 | 3 |
1 N.O. 1 N.C. |
VB6-30-10-Δ VB6-30-01-Δ |
16 | 9.6 | 2 | 3 | 5 | 5 | 1 | 2 | 3 |
1 N.O. 1 N.C. |
VB7-30-10-Δ VB7-30-01-Δ |
DC OPERATED | ||||||||||
12 | 6.8 | 1 | 2 | 3 | 1 | 1/2 | 1 | 3 | 1 N.O. 1 N.C. |
VBC6-30-10-Δ VBC6-30-01-Δ |
16 | 9.6 | 2 | 3 | 5 | 5 | 1 | 2 | 3 | 1 N.O. 1 N.C. |
VBC7-30-10-Δ VBC7-30-01-Δ |
MECHANICALLY INTERLOCKED WITH FLAT PIN CONNECTIONS
General Purpose AC1 |
Maximum Motor FLA AC3 |
3 Phase Motor Horsepower | Single Phase | Number of Power Poles |
Auxiliary Contacts |
Catalog Number | ||||
208V | 230V | 460V | 600V | 120V | 230V | |||||
AC OPERATED | ||||||||||
12 | 6.8 | 1 | 2 | 3 | 1 | 1/2 | 1 | 3 |
1 N.O. 1 N.C. |
VB6-30-10-FΔ VB6-30-01-FΔ |
16 | 9.6 | 2 | 3 | 5 | 5 | 1 | 2 | 3 |
1 N.O. 1 N.C. |
VB7-30-10-FΔ VB7-30-01-FΔ |
DC OPERATED | ||||||||||
12 | 6.8 | 1 | 2 | 3 | 1 | 1/2 | 1 | 3 | 1 N.O. 1 N.C. |
VBC6-30-10-FΔ VBC6-30-01-FΔ |
16 | 9.6 | 2 | 3 | 5 | 5 | 1 | 2 | 3 | 1 N.O. 1 N.C. |
VBC7-30-10-FΔ VBC7-30-01-FΔ |
MECHANICALLY INTERLOCKED WITH SOLDERING PIN CONNECTIONS
General Purpose AC1 |
Maximum Motor FLA AC3 |
3 Phase Motor Horsepower | Single Phase | Number of Power Poles |
Auxiliary Contacts |
Catalog Number | ||||
208V | 230V | 460V | 600V | 120V | 230V | |||||
AC OPERATED | ||||||||||
12 | 6.8 | 1 | 2 | 3 | 1 | 1/2 | 1 | 3 |
1 N.O. 1 N.C. |
VB6-30-10-PΔ VB6-30-01-PΔ |
16 | 9.6 | 2 | 3 | 5 | 5 | 1 | 2 | 3 |
1 N.O. 1 N.C. |
VB7-30-10-PΔ VB7-30-01-PΔ |
DC OPERATED | ||||||||||
12 | 6.8 | 1 | 2 | 3 | 1 | 1/2 | 1 | 3 | 1 N.O. 1 N.C. |
VBC6-30-10-PΔ VBC6-30-01-PΔ |
16 | 9.6 | 2 | 3 | 5 | 5 | 1 | 2 | 3 | 1 N.O. 1 N.C. |
VBC7-30-10-PΔ VBC7-30-01-PΔ |
∆ Coil voltage suffix. Refer to Coil Voltage Selection Chart and substitute the desired coil voltage suffix for the Δ.
COIL VOLTAGE SELECTION CHART
Volts | ||||||||||
12 | 24 | 42 | 48 | 110/125 | 110/120 | 220 | 220/240 | 380/415 | ||
AC 40-450 Hz | F | L | G | 1 | 2 | M | ||||
DC | U | Y | V | W | P | R |