Call Us Toll-Free: (877) 268-3700 | Mon-Fri: 8AM-5PM CST
Call Us Toll-Free: (877) 268-3700 | sales@grossautomation.com
A9 - AF750 COMBINATION STARTERS | DISCONNECT TYPE | NON-REVERSING | 3 PHASE | FUSIBLE

DESCRIPTION

  • Maximum UL/CSA horsepower ratings
  • Available with ABB non-fusible or fusible disconnect switches and MCP, thermal Magnetic or electronic trip type circuit breakers.
  • Compact space saving design
  • Double break contact design
  • Lowest possible contact bounce
  • UL Listed
STANDARD PART NUMBERS
UL Motor
Switching Current
Maximum Ratings - UL Listed UL Type 1
(Indoor Metal)
UL Type 3R
(Outdoor Metal)
Maximum Motor Horsepower Ratings    
200/208V 230/240V 460/480V 575/600V Fuse Clip
Rating
amp/volts
Catalog Number Catalog Number
UL RATED
9 2 2 5 7.5 30/600 11F1-2Δ1 11F3-2Δ1
11 3 3 7.5 10 30/600 21F1-2Δ1 21F3-2Δ1
17 5 5 10 15 30/600 31F1-2Δ1 31F3-2Δ1
28 7.5 10 20 25 60/600 41F1-2Δ2 41F3-2Δ2
34 10 10 25 30 60/600 51F1-2Δ2 51F3-2Δ2
42 10 15 30 40 60/600 61F1-2Δ2 61F3-2Δ2
54 15 20 40 50 100/600 71F1-2Δ3 71F3-2Δ3
65 20 25 50 50 100/600 81F1-2Δ3 81F3-2Δ3
80 25 30 60 75 200/600 91F1-2Δ4 91F3-2Δ4
110 30 40 75 100 200/600 A1F1-2Δ4 A1F3-2Δ4
130 40 50 100 125 200/600 B1F1-2Δ4 B1F3-2Δ4
156 50 60 125 150 400/600 C1F1-2Δ5 C1F3-2Δ5
192 60 75 150 200 400/600 D1F1-2Δ5 D1F3-2Δ5
248 75 100 200 250 400/600 E1F1-2Δ5 E1F3-2Δ5
302 100 100 250 300 400/600 F1F1-2Δ5 F1F3-2Δ5
414 125 150 350 400 600/600 G1F1-2Δ6 G1F3-2Δ6
480 150 - - - 600/600 H1F1-70Δ6 H1F3-70Δ6
480 - 200 400 500 800/600 H1F1-70Δ7 H1F3-70Δ7
590 200 250 500 600 1200/600 T1F1-70Δ8 T1F3-70Δ8
810 250 300 600 700 1200/600 U1F1-70Δ8 U1F3-70Δ8
NEMA Rated
  UL Type 1
(Indoor Metal)
UL Type 3R
(Outdoor Metal)
NEMA Size Continuous
Current
200V 230V 460/575V Fuse Clip
Rating
amp/volts
Catalog Number Catalog Number
00 9 1.5 1.5 2 30/600 J1F1-2Δ1 J1F3-2Δ1
0 18 3 3 5 30/600 K1F1-2Δ1 K1F3-2Δ1
1 27 - 7.5 10 30/600 L1F1-2Δ1 L1F3-2Δ1
1 27 7.5 - - 60/600 L1F1-2Δ2 L1F3-2Δ2
2 45 10 15 25 60/600 M1F1-2Δ2 M1F3-2Δ2
3 90 - - 50 100/600 N1F1-2Δ3 N1F3-2Δ3
3 90 25 30 - 200/600 N1F1-2Δ4 N1F3-2Δ4
4 135 40 50 100 200/600 P1F1-2Δ4 P1F3-2Δ4
5 270 75 100 200 400/600 Q1F1-2Δ5 Q1F3-2Δ5
6 540 150 - - 600/600 R1F1-2Δ6 R1F3-2Δ6
6 540 - 200 400 800/600 R1F1-2Δ7 R1F3-2Δ7
7 810 - 300 600 1200/600 S1F1-2Δ8 S1F3-2Δ8

 

UL Motor
Switching Current
Maximum Ratings - UL Listed UL Type 12
(Metal Dustight)
UL Type 4
(Watertight)
Maximum Motor Horsepower Ratings    
200/208V 230/240V 460/480V 575/600V Fuse Clip
Rating
amp/volts
Catalog Number Catalog Number
UL RATED
9 2 2 5 7.5 30/600 11F2-2Δ1 11F4-2Δ1
11 3 3 7.5 10 30/600 21F2-2Δ1 21F4-2Δ1
17 5 5 10 15 30/600 31F2-2Δ1 31F4-2Δ1
28 7.5 10 20 25 60/600 41F2-2Δ2 41F4-2Δ2
34 10 10 25 30 60/600 51F2-2Δ2 51F4-2Δ2
42 10 15 30 40 60/600 61F2-2Δ2 61F4-2Δ2
54 15 20 40 50 100/600 71F2-2Δ3 71F4-2Δ3
65 20 25 50 50 100/600 81F2-2Δ3 81F4-2Δ3
80 25 30 60 75 200/600 91F2-2Δ4 91F4-2Δ4
110 30 40 75 100 200/600 A1F2-2Δ4 A1F4-2Δ4
130 40 50 100 125 200/600 B1F2-2Δ4 B1F4-2Δ4
156 50 60 125 150 400/600 C1F2-2Δ5 C1F4-2Δ5
192 60 75 150 200 400/600 D1F2-2Δ5 D1F4-2Δ5
248 75 100 200 250 400/600 E1F2-2Δ5 E1F4-2Δ5
302 100 100 250 300 400/600 F1F2-2Δ5 F1F4-2Δ5
414 125 150 350 400 600/600 G1F2-2Δ6 G1F4-2Δ6
480 150 - - - 600/600 H1F2-70Δ6 H1F4-70Δ6
480 - 200 400 500 800/600 H1F2-70Δ7 H1F4-70Δ7
590 200 250 500 600 1200/600 T1F2-70Δ8 T1F4-70Δ8
810 250 300 600 700 1200/600 U1F2-70Δ8 U1F4-70Δ8
NEMA Rated
  UL Type 12
(Metal Dustight)
UL Type 4
(Watertight)
NEMA Size Continuous
Current
200V 230V 460/575V Fuse Clip
Rating
amp/volts
Catalog Number Catalog Number
00 9 1.5 1.5 2 30/600 J1F2-2Δ1 J1F4-2Δ1
0 18 3 3 5 30/600 K1F2-2Δ1 K1F4-2Δ1
1 27 - 7.5 10 30/600 L1F2-2Δ1 L1F4-2Δ1
1 27 7.5 - - 60/600 L1F2-2Δ2 L1F4-2Δ2
2 45 10 15 25 60/600 M1F2-2Δ2 M1F4-2Δ2
3 90 - - 50 100/600 N1F2-2Δ3 N1F4-2Δ3
3 90 25 30 - 200/600 N1F2-2Δ4 N1F4-2Δ4
4 135 40 50 100 200/600 P1F2-2Δ4 P1F4-2Δ4
5 270 75 100 200 400/600 Q1F2-2Δ5 Q1F4-2Δ5
6 540 150 - - 600/600 R1F2-2Δ6 R1F4-2Δ6
6 540 - 200 400 800/600 R1F2-2Δ7 R1F4-2Δ7
7 810 - 300 600 1200/600 S1F2-2Δ8 S1F4-2Δ8

 

UL Motor
Switching Current
Maximum Ratings - UL Listed UL Type 4X
(Stainless Steel)
UL Type 1, 3R, 4, 4X & 12
(Plastic)
Maximum Motor Horsepower Ratings    
200/208V 230/240V 460/480V 575/600V Fuse Clip
Rating
amp/volts
Catalog Number Catalog Number
UL RATED
9 2 2 5 7.5 30/600 11FX-2Δ1 11FP-2Δ1
11 3 3 7.5 10 30/600 21FX-2Δ1 21FP-2Δ1
17 5 5 10 15 30/600 31FX-2Δ1 31FP-2Δ1
28 7.5 10 20 25 60/600 41FX-2Δ2 41FP-2Δ2
34 10 10 25 30 60/600 51FX-2Δ2 51FP-2Δ2
42 10 15 30 40 60/600 61FX-2Δ2 61FP-2Δ2
54 15 20 40 50 100/600 71FX-2Δ3 71FP-2Δ3
65 20 25 50 50 100/600 81FX-2Δ3 81FP-2Δ3
80 25 30 60 75 200/600 91FX-2Δ4 91FP-2Δ4
110 30 40 75 100 200/600 A1FX-2Δ4 A1FP-2Δ4
130 40 50 100 125 200/600 B1FX-2Δ4 B1FP-2Δ4
156 50 60 125 150 400/600 C1FX-2Δ5 C1FP-2Δ5
192 60 75 150 200 400/600 D1FX-2Δ5 D1FP-2Δ5
248 75 100 200 250 400/600 E1FX-2Δ5 E1FP-2Δ5
302 100 100 250 300 400/600 F1FX-2Δ5 F1FP-2Δ5
414 125 150 350 400 600/600 G1FX-2Δ6 -
480 150 - - - 600/600 H1FX-70Δ6 -
480 - 200 400 500 800/600 H1FX-70Δ7 -
590 200 250 500 600 1200/600 T1FX-70Δ8 -
810 250 300 600 700 1200/600 U1FX-70Δ8 -
NEMA Rated
  UL Type 4X
(Stainless Steel)
UL Type 1, 3R, 4, 4X & 12
(Plastic)
NEMA Size Continuous
Current
200V 230V 460/575V Fuse Clip
Rating
amp/volts
Catalog Number Catalog Number
00 9 1.5 1.5 2 30/600 J1FX-2Δ1 J1FP-2Δ1
0 18 3 3 5 30/600 K1FX-2Δ1 K1FP-2Δ1
1 27 - 7.5 10 30/600 L1FX-2Δ1 L1FP-2Δ1
1 27 7.5 - - 60/600 L1FX-2Δ2 L1FP-2Δ2
2 45 10 15 25 60/600 M1FX-2Δ2 M1FP-2Δ2
3 90 - - 50 100/600 N1FX-2Δ3 N1FP-2Δ3
3 90 25 30 - 200/600 N1FX-2Δ4 N1FP-2Δ4
4 135 40 50 100 200/600 P1FX-2Δ4 P1FP-2Δ4
5 270 75 100 200 400/600 Q1FX-2Δ5 Q1FP-2Δ5
6 540 150 - - 600/600 R1FX-2Δ6 -
6 540 - 200 400 800/600 R1FX-2Δ7 -
7 810 - 300 600 1200/600 S1FX-2Δ8 -
Overload relay suffix code. Select from Overload Relay Selection Chart. Overload relays are required for all combination starters. If overload relay is provided by customer, substitute an "X" in place of the.
COIL VOLTAGE SELECTION CHART (A9-A300)
Hz Cntr Type Volts
    24 110 120 208 220 240 440 480 500 600
60 A 1   2 3   4 5 6   7
50 A 1 2     4       7  
COIL VOLTAGE SELECTION CHART (400-A750)
Hz Type 100 - 250 250 - 500
50/60 AF 70 71
CONTROL TRANSFORMER VOLTAGE SELECTION CHART
  Volts
Hz Type 200 - 208/120 240/120 460 - 480/120 575 - 600/120
50/60 A/AF A B C D
200 - 208/24 240/24 460 - 480/24 575 - 600/24
E F G H
CONTROL TRANSFORMER OPTION
   
Contactor Size VA Rating
A9 - A40 50
A50 - A75 75
A95 - A110 100
A145 - A185 150
A210 - A300 250
A400 - A460 150
A580 - A750 250
MAXIMUM SHORT CIRCUIT RATINGS FOR UL LISTED COMBINATION STARTERS
     
Contactor Size Switch/fuse at 600VAC KA at 600VAC
A9 CF30/30J 200
A12 CF30/30J
A16 CF30/30J
A26 F60/60J
A30 F60/60J
A40 F100/100J
A50 F100/100J
A63 OES200/200J
A75 OES200/200J
A95 OES200/200J
A110 OES200/200J
A145 OES400/400J
A185 OES400/400J
A210 OES400/400J
A260 OES400/400J or OES600/600J
A300 OES400/400J or OES600/600J
A400 OES600/600J
A460 OES800/800L
A580 OETL1200W/1200L fuses
A750 OETL1200W/1200L fuses