DESCRIPTION

  • Maximum UL/CSA horsepower ratings
  • Available with ABB non-fusible or fusible disconnect switches and MCP, thermal Magnetic or electronic trip type circuit breakers.
  • Compact space saving design
  • Double break contact design
  • Lowest possible contact bounce
  • UL Listed
STANDARD PART NUMBERS
UL Motor
Switching Current
Maximum Ratings - UL Listed UL Type 1
(Indoor Metal)
UL Type 3R
(Outdoor Metal)
UL Type 12
(Metal Dustight)
Maximum Motor Horsepower Ratings      
200/208V 230/240V 460/480V 575/600V Catalog Number Catalog Number Catalog Number
UL RATED
9 2 2 5 7.5 11N1-2Δ 11N3-2Δ 11N2-2Δ
11 3 3 7.5 10 21N1-2Δ 21N3-2Δ 21N2-2Δ
17 5 5 10 15 31N1-2Δ 31N3-2Δ 31N2-2Δ
28 7.5 10 20 25 41N1-2Δ 41N3-2Δ 41N2-2Δ
34 10 10 25 30 51N1-2Δ 51N3-2Δ 51N2-2Δ
42 10 15 30 40 61N1-2Δ 61N3-2Δ 61N2-2Δ
54 15 20 40 50 71N1-2Δ 71N3-2Δ 71N2-2Δ
65 20 25 50 50 81N1-2Δ 81N3-2Δ 81N2-2Δ
80 25 30 60 75 91N1-2Δ 91N3-2Δ 91N2-2Δ
110 30 40 75 100 A1N1-2Δ A1N3-2Δ A1N2-2Δ
130 40 50 100 125 B1N1-2Δ B1N3-2Δ B1N2-2Δ
156 50 60 125 150 C1N1-2Δ C1N3-2Δ C1N2-2Δ
192 60 75 150 200 D1N1-2Δ D1N3-2Δ D1N2-2Δ
248 75 100 200 250 E1N1-2Δ E1N3-2Δ E1N2-2Δ
302 100 100 250 300 F1N1-2Δ F1N3-2Δ F1N2-2Δ
414 125 150 350 400 G1N1-2Δ G1N3-2Δ G1N2-2Δ
480 150 200 400 500 H1N1-70Δ H1N3-70Δ H1N2-70Δ
590 200 250 500 600 T1N1-70Δ T1N3-70Δ T1N2-70Δ
810 250 300 600 700 U1N1-70Δ U1N3-70Δ U1N2-70Δ
NEMA Rated
  UL Type 1
(Indoor Metal)
UL Type 3R
(Outdoor Metal)
UL Type 12
(Metal Dustight)
NEMA Size Continuous
Current
200V 230V 460/575V Catalog Number Catalog Number Catalog Number
00 9 1.5 1.5 2 J1N1-2Δ J1N3-2Δ J1N2-2Δ
0 18 3 3 5 K1N1-2Δ K1N3-2Δ K1N2-2Δ
1 27 7.5 7.5 10 L1N1-2Δ L1N3-2Δ L1N2-2Δ
2 45 10 15 25 M1N1-2Δ M1N3-2Δ M1N2-2Δ
3 90 25 30 50 N1N1-2Δ N1N3-2Δ N1N2-2Δ
4 135 40 50 100 P1N1-2Δ P1N3-2Δ P1N2-2Δ
5 270 75 100 200 Q1N1-2Δ Q1N3-2Δ Q1N2-2Δ
6 540 150 200 400 R1N1-70Δ R1N3-70Δ R1N2-70Δ
7 810 - 300 600 S1N1-70Δ S1N3-70Δ S1N2-70Δ

 

UL Motor
Switching Current
Maximum Ratings - UL Listed UL Type 4
(Watertight)
UL Type 4X
(Stainless Steel)
UL Type1, 3R, 4 4X & 12
(Plastic)
Maximum Motor Horsepower Ratings      
200/208V 230/240V 460/480V 575/600V Catalog Number Catalog Number Catalog Number
UL RATED
9 2 2 5 7.5 11N4-2Δ 11NX-2Δ 11NP-2Δ
11 3 3 7.5 10 21N4-2Δ 21NX-2Δ 21NP-2Δ
17 5 5 10 15 31N4-2Δ 31NX-2Δ 31NP-2Δ
28 7.5 10 20 25 41N4-2Δ 41NX-2Δ 41NP-2Δ
34 10 10 25 30 51N4-2Δ 51NX-2Δ 51NP-2Δ
42 10 15 30 40 61N4-2Δ 61NX-2Δ 61NP-2Δ
54 15 20 40 50 71N4-2Δ 71NX-2Δ 71NP-2Δ
65 20 25 50 50 81N4-2Δ 81NX-2Δ 81NP-2Δ
80 25 30 60 75 91N4-2Δ 91NX-2Δ 91NP-2Δ
110 30 40 75 100 A1N4-2Δ A1NX-2Δ A1NP-2Δ
130 40 50 100 125 B1N4-2Δ B1NX-2Δ B1NP-2Δ
156 50 60 125 150 C1N4-2Δ C1NX-2Δ C1NP-2Δ
192 60 75 150 200 D1N4-2Δ D1NX-2Δ D1NP-2Δ
248 75 100 200 250 E1N4-2Δ E1NX-2Δ E1NP-2Δ
302 100 100 250 300 F1N4-2Δ F1NX-2Δ F1NP-2Δ
414 125 150 350 400 G1N4-2Δ G1NX-2Δ G1NP-2Δ
480 150 200 400 500 H1N4-70Δ H1NX-70Δ -
590 200 250 500 600 T1N4-70Δ T1NX-70Δ -
810 250 300 600 700 U1N4-70Δ U1NX-70Δ -
NEMA Rated
  UL Type 4
(Watertight)
UL Type 4X
(Stainless Steel)
UL Type1, 3R, 4 4X & 12
(Plastic)
NEMA Size Continuous
Current
200V 230V 460/575V Catalog Number Catalog Number Catalog Number
00 9 1.5 1.5 2 J1N4-2Δ J1NX-2Δ J1NP-2Δ
0 18 3 3 5 K1N4-2Δ K1NX-2Δ K1NP-2Δ
1 27 7.5 7.5 10 L1N4-2Δ L1NX-2Δ L1NP-2Δ
2 45 10 15 25 M1N4-2Δ M1NX-2Δ M1NP-2Δ
3 90 25 30 50 N1N4-2Δ N1NX-2Δ N1NP-2Δ
4 135 40 50 100 P1N4-2Δ P1NX-2Δ P1NP-2Δ
5 270 75 100 200 Q1N4-2Δ Q1NX-2Δ Q1NP-2Δ
6 540 150 200 400 R1N4-70Δ R1NX-70Δ -
7 810 - 300 600 S1N4-70Δ S1NX-70Δ -
Overload relay suffix code. Select from Overload Relay Selection Chart. Overload relays are required for all combination starters. If overload relay is provided by customer, substitute an "X" in place of the.
COIL VOLTAGE SELECTION CHART (A9-A300)
Hz Cntr Type Volts
    24 110 120 208 220 240 440 480 500 600
60 A 1   2 3   4 5 6   7
50 A 1 2     4       7  
COIL VOLTAGE SELECTION CHART (400-A750)
Hz Type 100 - 250 250 - 500
50/60 AF 70 71
CONTROL TRANSFORMER VOLTAGE SELECTION CHART
  Volts
Hz Type 200 - 208/120 240/120 460 - 480/120 575 - 600/120
50/60 A/AF A B C D
200 - 208/24 240/24 460 - 480/24 575 - 600/24
E F G H
CONTROL TRANSFORMER OPTION
   
Contactor Size VA Rating
A9 - A40 50
A50 - A75 75
A95 - A110 100
A145 - A185 150
A210 - A300 250
A400 - A460 150
A580 - A750 250