Call Us Toll-Free: (877) 268-3700 | Mon-Fri: 8AM-5PM CST
Call Us Toll-Free: (877) 268-3700 | sales@grossautomation.com
A9 - AF750 COMBINATION STARTERS | DISCONNECT TYPE | REVERSING | 3 PHASE | FUSIBLE |

DESCRIPTION

  • Maximum UL/CSA horsepower ratings
  • Available with ABB non-fusible or fusible disconnect switches and MCP, thermal Magnetic or electronic trip type circuit breakers.
  • Compact space saving design
  • Double break contact design
  • Lowest possible contact bounce
  • UL Listed
STANDARD PART NUMBERS
UL Motor
Switching Current
Maximum Ratings - UL Listed UL Type 1
(Indoor Metal)
UL Type 3R
(Outdoor Metal)
Maximum Motor Horsepower Ratings    
200/208V 230/240V 460/480V 575/600V Fuse Clip
Rating
amp/volts
Catalog Number Catalog Number
UL RATED
9 2 2 5 7.5 30/600 12F1-2Δ1 12F3-2Δ1
11 3 3 7.5 10 30/600 22F1-2Δ1 22F3-2Δ1
17 5 5 10 15 30/600 32F1-2Δ1 32F3-2Δ1
28 7.5 10 20 25 60/600 42F1-2Δ2 42F3-2Δ2
34 10 10 25 30 60/600 52F1-2Δ2 52F3-2Δ2
42 10 15 30 40 60/600 62F1-2Δ2 62F3-2Δ2
54 15 20 40 50 100/600 72F1-2Δ3 72F3-2Δ3
65 20 25 50 50 100/600 82F1-2Δ3 82F3-2Δ3
80 25 30 60 75 200/600 92F1-2Δ4 92F3-2Δ4
110 30 40 75 100 200/600 A2F1-2Δ4 A2F3-2Δ4
130 40 50 100 125 200/600 B2F1-2Δ4 B2F3-2Δ4
156 50 60 125 150 400/600 C2F1-2Δ5 C2F3-2Δ5
192 60 75 150 200 400/600 D2F1-2Δ5 D2F3-2Δ5
248 75 100 200 250 400/600 E2F1-2Δ5 E2F3-2Δ5
302 100 100 250 300 400/600 F2F1-2Δ5 F2F3-2Δ5
414 125 150 350 400 600/600 G2F1-2Δ6 G2F3-2Δ6
480 150 - - - 600/600 H2F1-70Δ6 H2F3-70Δ6
480 - 200 400 500 800/600 H2F1-70Δ7 H2F3-70Δ7
590 200 250 500 600 1200/600 T2F1-70Δ8 T2F3-70Δ8
810 250 300 600 700 1200/600 U2F1-70Δ8 U2F3-70Δ8
NEMA Rated
  UL Type 1
(Indoor Metal)
UL Type 3R
(Outdoor Metal)
NEMA Size Continuous
Current
200V 230V 460/575V Fuse Clip
Rating
amp/volts
Catalog Number Catalog Number
00 9 1.5 1.5 2 30/600 J2F1-2Δ1 J2F3-2Δ1
0 18 3 3 5 30/600 K2F1-2Δ1 K2F3-2Δ1
1 27 - 7.5 10 30/600 L2F1-2Δ1 L2F3-2Δ1
1 27 7.5 - - 60/600 L2F1-2Δ2 L2F3-2Δ2
2 45 10 15 25 60/600 M2F1-2Δ2 M2F3-2Δ2
3 90 - - 50 100/600 N2F1-2Δ3 N2F3-2Δ3
3 90 25 30 - 200/600 N2F1-2Δ4 N2F3-2Δ4
4 135 40 50 100 200/600 P2F1-2Δ4 P2F3-2Δ4
5 270 75 100 200 400/600 Q2F1-2Δ5 Q2F3-2Δ5
6 540 150 - - 600/600 R2F1-2Δ6 R2F3-2Δ6
6 540 - 200 400 800/600 R2F1-2Δ7 R2F3-2Δ7
7 810 - 300 600 1200/600 S2F1-2Δ8 S2F3-2Δ8

 

UL Motor
Switching Current
Maximum Ratings - UL Listed UL Type 12
(Metal Dustight)
UL Type 4
(Watertight)
Maximum Motor Horsepower Ratings    
200/208V 230/240V 460/480V 575/600V Fuse Clip
Rating
amp/volts
Catalog Number Catalog Number
UL RATED
9 2 2 5 7.5 30/600 12F2-2Δ1 12F4-2Δ1
11 3 3 7.5 10 30/600 22F2-2Δ1 22F4-2Δ1
17 5 5 10 15 30/600 32F2-2Δ1 32F4-2Δ1
28 7.5 10 20 25 60/600 42F2-2Δ2 42F4-2Δ2
34 10 10 25 30 60/600 52F2-2Δ2 52F4-2Δ2
42 10 15 30 40 60/600 62F2-2Δ2 62F4-2Δ2
54 15 20 40 50 100/600 72F2-2Δ3 72F4-2Δ3
65 20 25 50 50 100/600 82F2-2Δ3 82F4-2Δ3
80 25 30 60 75 200/600 92F2-2Δ4 92F4-2Δ4
110 30 40 75 100 200/600 A2F2-2Δ4 A2F4-2Δ4
130 40 50 100 125 200/600 B2F2-2Δ4 B2F4-2Δ4
156 50 60 125 150 400/600 C2F2-2Δ5 C2F4-2Δ5
192 60 75 150 200 400/600 D2F2-2Δ5 D2F4-2Δ5
248 75 100 200 250 400/600 E2F2-2Δ5 E2F4-2Δ5
302 100 100 250 300 400/600 F2F2-2Δ5 F2F4-2Δ5
414 125 150 350 400 600/600 G2F2-2Δ6 G2F4-2Δ6
480 150 - - - 600/600 H2F2-70Δ6 H2F4-70Δ6
480 - 200 400 500 800/600 H2F2-70Δ7 H2F4-70Δ7
590 200 250 500 600 1200/600 T2F2-70Δ8 T2F4-70Δ8
810 250 300 600 700 1200/600 U2F2-70Δ8 U2F4-70Δ8
NEMA Rated
  UL Type 12
(Metal Dustight)
UL Type 4
(Watertight)
NEMA Size Continuous
Current
200V 230V 460/575V Fuse Clip
Rating
amp/volts
Catalog Number Catalog Number
00 9 1.5 1.5 2 30/600 J2F2-2Δ1 J2F4-2Δ1
0 18 3 3 5 30/600 K2F2-2Δ1 K2F4-2Δ1
1 27 - 7.5 10 30/600 L2F2-2Δ1 L2F4-2Δ1
1 27 7.5 - - 60/600 L2F2-2Δ2 L2F4-2Δ2
2 45 10 15 25 60/600 M2F2-2Δ2 M2F4-2Δ2
3 90 - - 50 100/600 N2F2-2Δ3 N2F4-2Δ3
3 90 25 30 - 200/600 N2F2-2Δ4 N2F4-2Δ4
4 135 40 50 100 200/600 P2F2-2Δ4 P2F4-2Δ4
5 270 75 100 200 400/600 Q2F2-2Δ5 Q2F4-2Δ5
6 540 150 - - 600/600 R2F2-2Δ6 R2F4-2Δ6
6 540 - 200 400 800/600 R2F2-2Δ7 R2F4-2Δ7
7 810 - 300 600 1200/600 S2F2-2Δ8 S2F4-2Δ8

 

UL Motor
Switching Current
Maximum Ratings - UL Listed UL Type 4X
(Stainless Steel)
UL Type 1, 3R, 4, 4X & 12
(Plastic)
Maximum Motor Horsepower Ratings    
200/208V 230/240V 460/480V 575/600V Fuse Clip
Rating
amp/volts
Catalog Number Catalog Number
UL RATED
9 2 2 5 7.5 30/600 12FX-2Δ1 12FP-2Δ1
11 3 3 7.5 10 30/600 22FX-2Δ1 22FP-2Δ1
17 5 5 10 15 30/600 32FX-2Δ1 32FP-2Δ1
28 7.5 10 20 25 60/600 42FX-2Δ2 42FP-2Δ2
34 10 10 25 30 60/600 52FX-2Δ2 52FP-2Δ2
42 10 15 30 40 60/600 62FX-2Δ2 62FP-2Δ2
54 15 20 40 50 100/600 72FX-2Δ3 72FP-2Δ3
65 20 25 50 50 100/600 82FX-2Δ3 82FP-2Δ3
80 25 30 60 75 200/600 92FX-2Δ4 92FP-2Δ4
110 30 40 75 100 200/600 A2FX-2Δ4 A2FP-2Δ4
130 40 50 100 125 200/600 B2FX-2Δ4 B2FP-2Δ4
156 50 60 125 150 400/600 C2FX-2Δ5 C2FP-2Δ5
192 60 75 150 200 400/600 D2FX-2Δ5 D2FP-2Δ5
248 75 100 200 250 400/600 E2FX-2Δ5 E2FP-2Δ5
302 100 100 250 300 400/600 F2FX-2Δ5 F2FP-2Δ5
414 125 150 350 400 600/600 G2FX-2Δ6 -
480 150 - - - 600/600 H2FX-70Δ6 -
480 - 200 400 500 800/600 H2FX-70Δ7 -
590 200 250 500 600 1200/600 T2FX-70Δ8 -
810 250 300 600 700 1200/600 U2FX-70Δ8 -
NEMA Rated
  UL Type 4X
(Stainless Steel)
UL Type 1, 3R, 4, 4X & 12
(Plastic)
NEMA Size Continuous
Current
200V 230V 460/575V Fuse Clip
Rating
amp/volts
Catalog Number Catalog Number
00 9 1.5 1.5 2 30/600 J2FX-2Δ1 J2FP-2Δ1
0 18 3 3 5 30/600 K2FX-2Δ1 K2FP-2Δ1
1 27 - 7.5 10 30/600 L2FX-2Δ1 L2FP-2Δ1
1 27 7.5 - - 60/600 L2FX-2Δ2 L2FP-2Δ2
2 45 10 15 25 60/600 M2FX-2Δ2 M2FP-2Δ2
3 90 - - 50 100/600 N2FX-2Δ3 N2FP-2Δ3
3 90 25 30 - 200/600 N2FX-2Δ4 N2FP-2Δ4
4 135 40 50 100 200/600 P2FX-2Δ4 P2FP-2Δ4
5 270 75 100 200 400/600 Q2FX-2Δ5 Q2FP-2Δ5
6 540 150 - - 600/600 R2FX-2Δ6 -
6 540 - 200 400 800/600 R2FX-2Δ7 -
7 810 - 300 600 1200/600 S2FX-2Δ8 -
Overload relay suffix code. Select from Overload Relay Selection Chart. Overload relays are required for all combination starters. If overload relay is provided by customer, substitute an "X" in place of the.
COIL VOLTAGE SELECTION CHART (A9-A300)
Hz Cntr Type Volts
    24 110 120 208 220 240 440 480 500 600
60 A 1   2 3   4 5 6   7
50 A 1 2     4       7  
COIL VOLTAGE SELECTION CHART (400-A750)
Hz Type 100 - 250 250 - 500
50/60 AF 70 71
CONTROL TRANSFORMER VOLTAGE SELECTION CHART
  Volts
Hz Type 200 - 208/120 240/120 460 - 480/120 575 - 600/120
50/60 A/AF A B C D
200 - 208/24 240/24 460 - 480/24 575 - 600/24
E F G H
CONTROL TRANSFORMER OPTION
   
Contactor Size VA Rating
A9 - A40 50
A50 - A75 75
A95 - A110 100
A145 - A185 150
A210 - A300 250
A400 - A460 150
A580 - A750 250
MAXIMUM SHORT CIRCUIT RATINGS FOR UL LISTED COMBINATION STARTERS
     
Contactor Size Switch/fuse at 600VAC KA at 600VAC
A9 CF30/30J 200
A12 CF30/30J
A16 CF30/30J
A26 F60/60J
A30 F60/60J
A40 F100/100J
A50 F100/100J
A63 OES200/200J
A75 OES200/200J
A95 OES200/200J
A110 OES200/200J
A145 OES400/400J
A185 OES400/400J
A210 OES400/400J
A260 OES400/400J or OES600/600J
A300 OES400/400J or OES600/600J
A400 OES600/600J
A460 OES800/800L
A580 OETL1200W/1200L fuses
A750 OETL1200W/1200L fuses